Furuno NAVpilot-700 Marine Instruments User Manual


 
1. INTRODUCTION
1-3
1.2 How to Turn Power On, Off
*:A timer counts down the time that remains until the power goes off
When the heading sensor PG-500 (or PG-700) is connected, see the note at the bot-
tom of this page. A beep sounds and the equipment shows product information fol-
lowed by the results of the startup test. The start up test checks the ROM, RAM and
backup of the processor unit and control unit. The test also checks for the presence of
heading from the heading sensor and rudder angle information from the rudder refer-
ence unit.
If NG appears for any item, an error message, shown in the table below, appears. Fol-
low the information provided in the message to restore normal operation. If you cannot
restore normal operation, contact your dealer for information.
Note: When the Heading Sensor PG-500/PG-700 is connected, turn on the NAVpilot
and wait four minutes before you leave port. This allows time for the PG-500/PG-700
heading data to stabilize.
Control unit Key ON OFF
FAP-7001 POWER/BRILL Short-press Long-press*
FAP-7011 POWER/STBY Short-press Long-press*
FAP-7021 STBY/POWER Short-press Long-press*
Error message Meaning
BACK UP DATA IS BROKEN. USE FACTORY DE-
FAULT. PUSH ANY KEY TO CONTINUE.
Backup data is corrupted.
CAN NOT RECEIVE HEADING DATA. PLEASE
CHECK THE HEADING SENSOR. PUSH ANY KEY TO
CONTINUE.
Problem with heading sen-
sor.
SYSTEM HAS FAILED STARTUP TEST. PLEASE
CONTACT LOCAL FURUNO REPRESENTATIVE FOR
REPAIR. PUSH ENTER KNOB TO CONTINUE.
The system has failed the
startup test.
START UP TEST
PROCESSOR 6454007-**.**
CONTROLLER 6454011-**.**
ROM RAM BACKUP
PROCESSOR UNIT OK OK OK
CONTROLLER OK OK OK
HEADING SENSOR OK 359.9°
-------------------------------------------
RRU OK xx.x°
CONTROLLER ID 1
AUTO PILOT
NAVPILOT-700*
FURUNO ELECTRIC CO., LTD
**.** : Program version no.
* Or NAVPILOT-711, NAVPILOT-720
For Fantum Feedback
TM
, “FANTUM FEEDBACK” is displayed.