Furuno NAVpilot-700 Marine Instruments User Manual


 
3. ALARMS
3-3
3.4 Watch Alarm
The watch alarm periodically warns the helmsman to check the NAVpilot when in the
AUTO or NAV mode.
1. Rotate the Course control knob to select [WATCH ALARM] from the [ALARM]
menu then push the knob.
2. Rotate the Course control knob to select [OFF] or [ON] then push the knob. For
[OFF] got to step 5.
3. Rotate the Course control knob to select the current watch alarm value then
push the knob.
4. Rotate the Course control knob to set the time interval (1 to 99 min).
5. Push the Course control knob to confirm setting.
If the set time passes without operation, the buzzer sounds and the message "THE
SET TIME HAS PASSED" appears. Further, if three minutes elapses after the watch
alarm has sounded, the alarm becomes louder. Press any key to clear the alarm.
3.5 Deviation Alarm
The deviation alarm sounds in the AUTO and NAV modes when the heading deviates
more than the deviation alarm value.
1. Rotate the Course control knob to select the current setting for [DEVIATION
ALARM] from the [ALARM] menu then push the knob.
2. Rotate the Course control knob to set the degree of deviation then push the
knob.
ON
OFF