e-STUDIO3511/4511 ADJUSTMENT 3 - 54 November 2003 © TOSHIBA TEC
Notes:
1. When confirming and adjusting the gap between the developer sleeve and the doctor blade, insert
the gauges into the gap after rotating the developer sleeve so that its marking faces the doctor
blade.
2. While reattaching the black developer unit cover, set the latches securely.
3.11.2 Doctor-to-sleeve gap (color developer unit)
Adjustment tool to use : Doctor-sleeve jig
(5) Insert the gauge “0.50” of the doctor-sleeve
jig into the gap between the developer
sleeve and doctor blade and make sure that
the gauge can move smoothly in the front/
rear direction. In addition, confirm that the
gauge “0.60” cannot be inserted into the
gap.
Developer sleeve
Doctor-sleeve
jig
Doctor blade
Adjusting procedure:
(1) Take off the color developer unit from the
equipment.
(2) Remove 2 screws and take off the
developer material cover. Then discharge
the developer material.
Screw
Screw
Developer material cover
(3) Remove 4 screws and the toner-scattering
prevention seal holder.
Screw Toner-scattering prevention
seal holder
Fig. 3-1104
Fig. 3-1105
Fig. 3-1106