November 2003 © TOSHIBA TEC 5 - 139 e-STUDIO3511/4511 TROUBLESHOOTING
04/09
5) Perform the gamma automatic adjustment of the printer.
See “3.6.1 Automatic gamma adjustment” for details.
(6) Ask users to reset the user’s setting items and to restore the data/information. See the following
for the reset and the restore.
1) Printer driver
- Upload them in the “Administrator” menu of TopAccess.
2) F-code information, Template registering information, Address book
- Restore them in the “Administrator” menu of TopAccess
3) Department management data
- Import them in the “Administrator” menu of TopAccess.
4) Image data in the Electronic Filing
- Upload them in the “e-Filing” of TopAccess.
(7) Referring to the “FUNCTION LIST FOR MAINTENANCE” list which was printed beforehand,
perform the re-setting.
1) Print out the “FUNCTION LIST FOR MAINTENANCE” list after the formatting. (Refer to the
procedure of (2).)
2) While pressing [1] and [3] simultaneously, turn the power ON. (Function Mode)
3) Compare the lists which were printed before and after the formatting to check the setting
items having the different setting values. Set the value which was set before the formatting.
4) Turn the power OFF.
(8) Referring to the “FUNCTION” list which was printed beforehand, perform the re-setting of the
default setting of the FAX function.
1) Press the [USER FUNCTIONS] button.
2) Press the [ADMIN] button, enter the password, and then press the [ENTER] button.
3) Press the [FAX] button and then the [TERMINAL ID] button to set each item.
4) Press the [INITIAL SETUP] button to set each item.
5.3.2 Replacing SYS board
<<CAUTION IN REPLACING the SYS board>>
The procedure for replacing the SYS board is as follows.
<After replacing the SYS board>
(1) Install DIMM (main memory) to the new SYS board (from the old SYS board).
(2) Install NVRAM to the new SYS board (from the old SYS board).
(3) Install NIC board to the new SYS board (from the old SYS board).