83
Settings
precise depth reading.
Before setting keel offset, measure the distance from the transducer to the lowest
part of the keel. If, for example, the keel is 3.5 feet below the transducer, it will be
input as –3.5 feet.
To set Keel Offset:
Highlight the 1. Keel Offset text box on the Installation menu and press
ENTER.
Use the keypad to enter the desired keel offset. Select 2. OK and press
ENTER.
Water Speed Calibration
When there are differences in speed data, Water Speed Calibration calibrates
data from a paddlewheel with GPS data. That ensures the
accuracy of speed data from your paddlewheel.
To calibrate Water Speed:
Select the 1. Water Speed Calibration text box
from the Installation menu and press ENTER.
The Water Speed Calibration keypad will appear.
Use the arrow keys to enter the percentage difference in speed 2.
data. Select OK and press ENTER.
NOTE: To input a keel offset that accounts for the distance
from the transducer to the water surface, you will enter a posi-
tive number. If the transducer is 1.5 feet below the waterline,
it will be input as +1.5 feet. That will give you a more precise
depth reading.
Water speed
calibration dialog box
NOTE: If the paddlewheel is reading a slower speed than the
GPS unit, you will input a positive (+) percentage. Conversely,
a negative (–) percentage will be entered if the paddlewheel is
reading a faster speed than the GPS unit.