Dell R730xd Life Jacket User Manual


 
Expanded operating temperature
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be
reported on the LCD and in the System Event Log.
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating
temperature (10°C to 35°C), the system can
operate continuously down to 5°C or as high
as 40°C.
For temperatures between 35°C and 40°C, de-
rate maximum allowable temperature by 1°C per
175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew
point.
NOTE: Outside the standard operating
temperature (10°C to 35°C), the system can
operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-
rate maximum allowable temperature by 1°C per
125 m above 950 m (1°F per 228 ft).
Expanded Operating Temperature Restrictions
Do not perform a cold startup below 5°C.
The operating temperature specified is for a
maximum altitude of 3050 m (10,000 ft).
160 W (10 core) processor is not supported.
Tape Backup Unit (TBU) is not supported.
Redundant power supplies are required.
Non Dell qualified peripheral cards and/or
peripheral cards greater than 25 W are not
supported.
PCIe SSD and GPU is not supported.
NOTE: The following additional restrictions
apply to PowerEdge R730xd.
Maximum 120 W processor supported on 3.5
inch hard drive chassis.
Maximum 145 W processor supported on 2.5
inch hard drive chassis.
Only SSDs are allowed in the hard drive slots at
the back of the 3.5 inch hard drive chassis.
Mid drive configurations and eight 3.5 inch
plus eighteen 1.8 inch SSD configurations is
not supported.
206