Furuno FCR-21x9-BB Marine RADAR User Manual


 
20. ALERTS
20-7
20.3 Alert Log
The [Alert] log stores the latest 10,000 alerts and displays the latest 500 alerts. To dis-
play the log, right-click the Alert list icon then select [Alert Log Window].
Note: The alert list cannot be opened while the radar is transmitting.
The log shows the following information for each alert:
You can select what type of alerts to display with the [Priority] and [Category] filters at
the top of the list. The list can be sorted by [Priority], [Cat.], [Description] or [Occurred
Time]. Click the corresponding column title to sort. To find detailed information about
an alert, select it to show detailed information in the [Detail] box. To search the log,
enter text in the [Log Search] box then click the [Find] button. You can save the con-
tents of the log to a USB flash memory, in .dat format, by clicking the [Export Log] but-
ton.
20.4 Alert Reception from Connected Sensors
An "ALR receive and ACK transmit" communication is available for every serial line.
ALR message from the sensor includes information about alert on sensor. This alert
is presented though the normal alert system of this system. When you acknowledge it
then an ACK message is sent to the sensor to perform remote acknowledge.
This interface is based on IEC 61162-1 and IEC 80/520/INF.
Priority of alert (Alarm, Warning, Caution)
Category of alert (A, B or C)
• Description of alert
• Source of alert
• Occurred Time (UTC)
ACKed Time (UTC)
• Rectified Time (UTC)
Priority
Category
Time
generated
Alert text
Alert no.
Alarm Details
Category
filter
Source
Priority
filter