Furuno FCR-2807 Marine RADAR User Manual


 
20. Alerts
20-19
Alert number 251: RADOV NO AZIMUTH 6/13
------------------------------------
NO AZIMUTH AVAILABLE FOR RADAR
OVERLAY. CHECK CONNECTORS AND
CABLING FOR RADAR OVERLAY
Alert number 252: RADOV NO TRIGGER 6/13
------------------------------------
NO TRIGGER AVAILABLE FOR RADAR
OVERLAY. CHECK CONNECTORS AND
CABLING FOR RADAR OVERLAY
Alert number 253: RADOV NO VIDEO /14
------------------------------------
NO VIDEO AVAILABLE FOR RADAR
OVERLAY. CHECK ADJUSTMENT OF GAIN ON
ON RADAR OVERLAY. CHECK CONNECTORS
AND CABLING FOR RADAR OVERLAY
Alert number 254: RADOV NO GYRO 6/13
------------------------------------
NO HEADING REFERENCE AVAILABLE FOR
ARPA PROCESSOR WHICH IS SOURCE FOR
RADAR OVERLAY. CHECK ARPA PROCESSOR
Alert number 256: LAN RADAR CONNECT FAILURE 5/12
------------------------------------
FAILURE TO ESTABLISH LAN CONNECTION
FOR ARPA FEATURES BETWEEN ECDIS
PROCESSOR AND ARPA PROCESSOR.
CHECK LAN CONNECTORS AND CABLES
POWER ON/OFF AND REINSTALL ECDIS SW.
Alert number 257: LAN RADAR DLL FAILURE 5/12
------------------------------------
FAILURE INSIDE ECDIS PROCESSOR
BETWEEN DLL INTERFACE SW AND ECDIS
SOFTWARE. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
Alert number 259: RADOV NO ECHODATA 7/14
------------------------------------
FAILURE TO RECEIVE RADAR ECHO DATA
FROM ARPA PROCESSOR OVER LAN
CONNECTION CHECK LAN CONNECTORS AND
CABLES. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
Alert number 260: TT dangerous target 2/9
---------------------------------------
Alert number 261: TT Target in ACQ ZONE 6/13
---------------------------------------
Alert number 262: TT lost target 6/13
---------------------------------------
Alert number 263: Radar STBY Warning 13/13
---------------------------------------
Alert number 264: TT Auto ACQ 100% full 6/13
---------------------------------------
Alert number 265: TT Auto ACQ 95% full 7/14
---------------------------------------
Alert number 266: TT Man ACQ 100% full 6/13
---------------------------------------