Furuno FCR-2807 Marine RADAR User Manual


 
FURUNO
FCR-2107(-BB,-D)/FCR-2807(-D) Series
SP - 4 E3559S01C-M
5. POWER SUPPLY
5.1 Display unit 100-230 VAC, 1ø, 50/60 Hz, 0.6-0.3A
5.2 Radar units FCR-2117
(-BB,-D)
/2817
(-D)
:
100-115 VAC, 1ø, 50/60 Hz: 2.6A
1
/3.0A
2
220-230 VAC, 1ø, 50/60 Hz: 1.6A
1
/1.7A
2
FCR-2127
(-BB,-D)
/2827
(-D)
:
100-115 VAC, 1ø, 50/60 Hz: 3.0A
1
/3.4A
2
220-230 VAC, 1ø, 50/60 Hz: 1.8A
1
/1.9A
2 1
24 rpm,
, 2
42 rpm
FCR-2137S
(-BB,-D)
/2837S
(-D)
/2837SW
(-D)
:
100-115 VAC, 1ø, 50/60 Hz: 3.0A
1
/3.0A
2
220-230 VAC, 1ø, 50/60 Hz: 1.7A
1
/1.7A
2
FCR-2827W(-D):
100-115 VAC, 1ø, 50/60 Hz: 3.2A (24 rpm)
220-230 VAC, 1ø, 50/60 Hz: 1.8A (24 rpm)
5.3 Chart processor unit 100-230 VAC, 1ø, 50/60 Hz: 1.5A-0.5A
5.4 Switching hub 100-230V AC, 1ø, 50/60 Hz: 0.1A
5.5 S-band antenna
Model Antenna voltage input (at wind speed 100 kt)
200 VAC,
3ø, 50 Hz/
220 VAC,
3ø, 60 Hz
380 VAC,
3ø, 50 Hz/
440 VAC
3ø, 60 Hz
220 VAC,
3ø, 50 Hz
(HSC)
220 VAC,
3ø, 60 Hz
(HSC)
440 VAC,
3ø, 60 Hz
(HSC)
FCR-2137S(-BB,-D) 3.0A 1.5A 3.5A 3.5A 1.7A
FCR-2837S(-D) 3.0A 1.5A 3.5A 3.5A 1.7A
FCR-2837SW(-D) 3.0A 1.5A - - -
6. ENVIRONMENTAL CONDITIONS
6.1 Useable temperature range
Antenna unit -25°C to +55°C (storage +70°C)
Display unit, processor units, control unit, power supply, transceiver
-15°C to +50°C
6.2 Relative humidity 93±3% at 40°C
6.3 Waterproofing
Antenna unit IPX6 (IEC 60529)
Display unit, processor units, control unit, power supply:
IPX0 (IEC 60529)
Switching hub IPX0 (IEC 60529)
6.4 Vibration - From 2 Hz to 5 Hz to up to 13.2 Hz with an excursion of
±1 mm ±10%
-13.2 Hz to 100 Hz with a constant maximum acceleration of
7 m/s
2