Furuno FR-1760DS Marine RADAR User Manual


 
4-11
7. Open jumpers JP1, JP2 and JP3 on the AC power supply board. Short JP4 on the AC
power supply board.
Ship's main JP1 JP2 JP3 JP4
100 VAC short short short open
220 VAC open open open short
Figure 4-12 AC power supply board, jumper settings for 220 VAC
8. Reassemble the display unit.
9. Change two fuses from 10A to 5A on the rear panel.
Ship's main F1351 F1352
100 VAC 10A 10A
220 VAC 5A 5A