Modular ICS Companion Installer Guide P0992639 01
Event messages
Event message display Cause
(U.S. only) Unable to activate all registered
portables. The system ran out of portable
credits. One event is generated per portable
that failed to activate. The repetition of the
corresponding alarm code 59 indicates how
many additional credits must be purchased.
The base station (on port 0103 in this case)
cannot successfully receive the data image.
Both radios belonging to the base station are
disabled. This may occur if the flash EEPROM
is faulty. Two events are raised: one for the B1
channel radio (as in this case) and another for
the B2 channel radio. A corresponding alarm
code 53 occurs.
The base station (on port 0103 in this case)
cannot be written to during data transfer.
Both radios belonging to the base station are
disabled. The base station flash EEPROM is
faulty. Two events are raised: one for the B1
channel radio (as in this case) and another for
the B2 channel radio. A corresponding alarm
code 53 occurs.
The base station (on port 0103 in this case)
cannot be synchronized with the other base
stations in the system.
Both radios belonging to the base station are
disabled. The base station hardware is faulty.
Two events are raised: one for the B1 channel
radio (as in this case) and another for the B2
channel radio. A corresponding alarm code 53
occurs.
A B2 channel radio (radio 2 on port 0103 in this
case) cannot be synchronized with other radios
because of system overload.
Evt:275-3546 S8
Evt:301-1031 S5
Evt:302-1031 S5
Evt:303-1031 5