Furuno 2839S Marine RADAR User Manual


 
2. WIRING
2-14
2.4.2 How to connect cables inside the processor unit
Fabrication
Fabricate JIS cables as shown below to connect them to the WAGO connectors on
the I/O Board 24P0124 inside the processor unit.
For locations of cables and cores, see the sticker on the reverse side of the top cover.
(All dimensions in millimeters)
L
5
Shield
Armor
Clamp here by cable clamp.
Vinyl tape
After exposing cores,
wind shield around the armor.
Length of “L”
6
30
TTYCS-4, TTYCSLA-4,
TTYCS-1Q, TTYCSLA-1Q
TTYCS-10, TTYCSLA-10
400
380
Cable type (JIS)
Fabrication of TTYCS series
Fabrication of TTYCSLA series
L
Sheath
Clamp here by cable clamp.
Vinyl tape
6
30
Drain wire
100
5
Pass the vinyl sheath (local supply)
onto the drain wire, then attach the
crimp-on lug (preattached to the
earth clamp on the processor unit) to it.
Cable tie
(supplied)
Cable tie
(supplied)
Processor unit, cover removed
Crimp-on lugs
for drain wires
Procedures
1. Twist the conductor.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is ecure.
Terminal opener
Wiring for WAGO connector
WAGO connector
Wire
Twist
Press downward.