Furuno 2839S Marine RADAR User Manual


 
3. SETTING AND ADJUSTMENT
3-5
QV ECHO LEVEL
Set the detection level of echoes. The setting range is 1 to 31.
TT W/O GYRO
If a gyrocompass is not connected, select the TT function, ON (working) or OFF (no
working).
ACQ PRESET
Show the ACQ PRESET menu.
LAND SIZE: Set the land size in units of 100 m. The setting range is 100 to 3000 m.
ANT SELECT: Set the antenna radiator type of your radar.
AUTO ACQ CORRE: Set the correction count of automatic acquisition. The setting
range is 3 to 10.
AUTO ACQ WEED: Set the cancel count of automatic acquisition. THe setting
range is 1 to 5.
TRACK PRESET
Show the TRACK PRESET menu.
GATE SIZE: Set the gate size among S, M, L or LL.
FILTER RESPONSE: Set the filter response function. The setting range is 1 to 4.
LOST COUNT: Set the lost count. The setting range is 1 to 20.
MAX SPEED: No use.
TRACKING MODE: Set the tracking mode among 1 to 4.
START TIME TGT VECT: Choose time which a vector appears after acquisition,
TIME or SCAN and set seconds or scan counts.
TT SENSOR DATA
Show the TT status.
TT DETAIL DATA
Show the information for TT target.
DEFAULT
Restore the TT setting to the default setting.