2. WIRING
2-41
Input method (MC-3010A only)
Select the method of the analog data input, power voltage or power current.
Note 1: The input must not exceed the range of the input voltage, to prevent malfunc-
tion.
-Setting for voltage input: -10V to +10V or 0 to 10V (depending on the setting)
-Setting for contact input: Voltage 4mA to 20mA.
Note 2: When changing the input method, turn off the MC-3010A and on again to re-
flex it.
Power voltage: Input the amount of power voltage change to the operational ampli-
fier.
Power current: Pass the power current to the shunt resistor, 1kΩ/parallel (combined
resistance: 500Ω) to input the amount of voltage change at the both ends of the re-
sistor to the operational amplifier.
Jumper block J3 to J5 Input method
3-4 OPEN Power voltage (default setting)
SHORT Power current
AN-IN
AN-GND
CURR-JP1
AN +15V
AN GND AN -15V
Opeamp
Vin
InGnd
+VS1
-VS1
+VS2
-VS2
OutGnd
+15V
GND
-15V
Voltage
source
Load
Jumper: open
1kΩ 1% 0.5Wx2
CURR-JP2
AN-IN
AN-GND
CURR-JP1
CURR-JP2
AN +15V
AN GND AN -15V
Opeamp
Vin
InGnd
+VS1
-VS1
+VS2
-VS2
OutGnd
+15V
GND
-15V
Current
source
Load
Jumper short
1kΩ 1% 0.5Wx2
Use NH connector
and AWG24 cable.