Furuno 2839S Marine RADAR User Manual


 
APPENDIX 2 ROD TERMINALS
AP-5
MC-3020D, MC-DIN Board (24P0116)
*: Pin #1 and 5: no cable connection. However the jumper connection is necessary between #1
and 2 and #5 and 6 depending on the input specification.
Connector # Pin # Signal name Rod terminal to use Connected cable
J1
1 24V_IN AI 0.34-6 TQ (blue)
MC1.5-W-Lxxx
2 24V_GND
3 MODBUS-A AI 0.14-8 GY (gray)
4MODBUS-B
5GND
Connector # Pin # Signal name Rod terminal to use Connected cable
J2
1 24V_OUT AI 0.34-6 TQ (blue)
MC1.5-W-Lxxx
2 24V_GND
3 MODBUS-A AI 0.14-8 GY (gray)
4MODBUS-B
5GND
Connector # Pin # Signal name Rod terminal to use Connected cable
J3*
1 DV12V_OUT1
AI 1-6 RD (red) MPYC-12
2 DIGI_IN1
3 DIGI_RTN1
4GND
5 DC12V_OUT2
6 DIGI_IN2
7 DIGI_RTN2
8GND
Connector # Pin # Signal name Rod terminal to use Connected cable
J4*
1 DV12V_OUT3
AI 1-6 RD (red) MPYC-12
2 DIGI_IN3
3 DIGI_RTN3
4GND
5 DC12V_OUT4
6 DIGI_IN4
7 DIGI_RTN4
8GND
Connector # Pin # Signal name Rod terminal to use Connected cable
J5*
1 DV12V_OUT5
AI 1-6 RD (red) MPYC-12
2 DIGI_IN5
3 DIGI_RTN5
4GND
5 DC12V_OUT6
6 DIGI_IN6
7 DIGI_RTN6
8GND