4-14
Installing Hardware Options
For use with 350-MHz or greater Intel processor-based servers only
Writer: Cheri Stewart Project: Compaq ProLiant 3000 Servers Setup and Installation Guide Comments: 179776-002
File Name: E-CH04.DOC Last Saved On: 1/12/99 1:28 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Fan 3
(IO)
Fan 2
(CPU Redundant)
Fan 4 (IO Redundant)
Fan 1
(CPU)
Figure 4-10. Fan header location
Accessing Drive Cage and Media Bays
These instructions cover the removal of the hot-plug SCSI drive cage and
removable media cage, installation of the Simplex Enable board, and
installation of optional tape drive.
NOTE
: Installation of the Simplex Enable board disables controller duplexing
of the internal SCSI drives. Refer to the
Compaq ProLiant 3000 Cabling
Guidelines Reference Guide
for more information on configurating duplex and
simplex modes.
NOTE
: Your drive cage may differ from the model illustrated.
Remove Drive Cage
1. Prepare the server for installation. See section "Preparing the Server,"
outlined earlier in this chapter.
2. Loosen the thumbscrews on the front of the drive cage. See
Figure 4-11.
3. Pull out the latch at the back of the drive cage (shown in Figure 4-12)
and pull out the drive cage 2 to 3 inches to allow better access to cables.