Lucent Technologies PA-8500 Life Jacket User Manual


 
Using a digital voltmeter (DVM), measure the DC input voltage by connecting the leads to the input voltage test
points below the DC input connector. Connect the black lead to the 48V (black) test point; connect the red lead to
the -48V (red) test point. Verify that the voltage is within the range of -40.5 VDC to -60.0 VDC.
3.
If the input voltage is not within the specified range, do not proceed to the next step. Verify
the DC power input source.
Since it is recommended that you limit the times the system is powered up and down, proceed to the system
console instructions (See Section 2.2 Installing the System Console later in this chapter) before completing Step 5.
4.
Turn on the cabinet MAIN power switches. The cabinet power supply lights are illuminated, indicating that the
system is receiving power. If the lights do not illuminate, check the following:
5.
Incoming power sources
Power cable connections to the power sources and cabinet
The polarity of the power cables. See Figure 2.10 for power-cable polarity information; for additional electrical
wiring information, see Appendix A of the DNCP Series 400/400-CO (PA-8500): Site Planning Guide (R454).)
If the power cord or the power source is not the cause of the problem, refer to the FTX Operating System: DNCP
Series 400/400-CO (PA-8500) Operation and Maintenance Guide (RXXX) for further system troubleshooting,
Chapter 2