Samsung iDCS100 Boating Equipment User Manual


 
3-2
Chapter 3
i
DCS100 Specifications
Environmental Limits
OPERATING TEMPERATURE
32–104 °F / 0–40 °C
STORAGE TEMPERATURE 13–158 °F / -10.5–70 °C
HUMIDITY 10%–90% non-condensing
Cable Requirements
EQUIPMENT CABLE AWG / mm MAX METRES
DIGITAL KEYSET 1 PR. TWISTED #24 / 0.5 400
ADD-ON MODULE 1 PR. TWISTED #24 / 0.5 400
SINGLE LINE STATION 1 PR. TWISTED #24 / 0.5 1000
DOOR PHONE 2 PR. TWISTED #24 / 0.5 100*
*This is the maximum distance a door phone can be from the DPIM. The DPIM can be up to 274 cable
metres from the KSU.
Power Supply
RESERVE POWER DURATION ESTIMATES (IN MINUTES)*
UPS CAPACITY IN VOLT AMPS (VA)
NO. OF STATIONS
250 400 450 600 900 1250 2000
4
65 160 200 245 360 490 930
8
45 110 135 160 240 320 625
12
40 90 115 140 200 280 535
16
30 75 90 110 160 220 415
24
25 50 70 85 120 175 380
32
20 45 60 75 100 150 330
*These are approximate values (in minutes) based on an idle system. The greater the C.O. line activity
on the system, the lower these readings will become. In addition, specific UPS devices, due to their in-
ternal construction, can have greater or lesser values.