Sherwood CR2709 Scuba Diving Equipment User Manual


 
20
• If a Low Battery Condition exists when the unit is activated (by pressing the button), the Battery icon will appear flash-
ing once per second for 5 seconds followed by shutdown of the unit.
• If the button is not pressed to activate the unit prior to a dive, and a Low Battery Condition exists, the Low Battery icon
will appear flashing as a warning upon descent past 4 feet (1.2 meters). No other information will be displayed and the
unit will not enter Dive Mode.
• If the unit did not display the Low Battery icon 'prior to' entering the Dive Mode, and a Low Battery Condition occurs
during the dive, there will be sufficient Battery power to maintain unit operation for the 'remainder of that dive'. The
Low Battery icon will appear upon surfacing when the TIME (or WET) screen is displayed.
OPERATING TEMPERATURE
The INSIGHT will operate in water temperatures from 28° to 95° F (-2 to 35 °C) and out of the water from 20° to 140°F (-6 to
60 °C). At extremely low temperatures, the LCD may become sluggish, but this will not affect its accuracy. If stored or trans-
ported in extremely low temperature areas (below freezing), warm the unit and battery with body heat before diving.
It is possible to damage the electronics if left exposed to direct sunlight, or in a hot confined space (like a car trunk). Af-
ter diving, cover it and keep it out of the sun. If inadvertently left in the direct sunlight, the LCD display may become totally
black. If this occurs, immediately immerse it in water. The display should recover its normal appearance after a few minutes.
Damage from excess heat, or cold, is not covered by the two year limited warranty.