Sherwood CR2709 Scuba Diving Equipment User Manual


 
46
A
S
> Depressing and holding the S button scrolls upward through the Set Points at a rate of 8 per second until released.
> Pressing and releasing the S button momentarily and repeatedly (< 2 sec each time) steps upward through the Set Points
1 at a time.
> Pressing and releasing the A button saves the Set Point and/or advances to SET RESERVE TIME ALARM.
> Depressing both buttons for 2 seconds reverts to the TIME/WET screen.
• Operation reverts to the TIME/WET screen if neither button is pressed in 2 minutes.
SET RESERVE TIME ALARM ON/OFF
The RESERVE TIME (RES) is the Dive Time Remaining which is a display of No Deco Time or O2 Time, the least available
at that moment. Whichever decreases to the Value set will sound the Alarm.
Factory set ON, the RESERVE TIME ALARM can also be set OFF. When set OFF, the Alarm will not sound as Dive Time
Remaining decreases toward 0 minutes.
To access SET RESERVE TIME ALARM while viewing the SET 2 GO TO screen, press/release the
A button (5 or 6 times) until the Set screen appears (Fig. 44) -
• Alpha graphics RES and AL
• Set Point graphic ON (or OFF) flashing, with TIME icon
> Pressing and releasing the S button toggles between ON and OFF.
> Pressing and releasing the A button saves the Set Point and advances to SET RES TIME VALUE (if
set ON) or SET DECO ALARM (if set OFF).
> Depressing both buttons for 2 seconds reverts to the TIME/WET screen.
Fig. 44 - Set Reserve
Time Alarm