92
Activation:
• Manual - push button (recommended)
• Automatic - by immersion in water, if set ON
• WET graphic indicates Wet Contacts are bridged (unit must be dried prior to transport or storage).
• Automatically set for AIR Mode operation upon activation
• Remains set for AIR Mode unless the Operating Mode is set for Nitrox or Gauge.
• Cannot be manually activated deeper than 4 FT (1.2 M), if the Water Activation feature is set OFF.
• Cannot be activated at elevations higher than 14,000 feet (4,270 meters)
Shutoff:
• Automatically shuts Off if no dive is made within 2 hours after initial activation. Reactivation required.
• Automatically shuts Off 24 hours after last dive (will reactivate if the Wet Activation is set ON and the unit becomes Wet).
• Cannot be shut Off manually.
Setting FO2:
• Nitrox Set Points from 21 to 50 %
• If set for 21%, remains set for 21% until changed
• If set for >21%, it reverts to 50% 10 minutes after the dive, if the FO2 Default is set ON. If the FO2 Default is set OFF, the value will remain at
the number (%) set until changed or the unit shuts Off. Defaults to AIR Mode operation upon shutdown and reactivation.
Operating Temperature:
• In Water >> between 28 and 95 °F (-2 and 35 °C)
• In Air >> between 20 and 140 °F (-6 and 60 °C)
ACCESSORIES (optional items available from your Authorized Sherwood Dealer)
• Lens Guard
• PC download package (hardware and software)
• Battery Kit - includes 1 battery, 1 battery hatch o-ring, silicone grease
SPECIFICATIONS (CONTINUED)