43
INSIGHT
A
S
A
S
To access SET ASCENT ALARM while viewing the SET 2 GO TO screen, press/release the A button
(2 times) until the Set screen appears (Fig. 39) -
• Alpha graphics ASNT and AL
• Set Point graphic ON (or OFF), flashing
• ARI, all segments solid
> Pressing and releasing the S button toggles between ON and OFF.
> Pressing and releasing the A button saves the Set Point and/or advances to SET DEPTH
ALARM with the Set Point flashing.
> Depressing both buttons for 2 seconds reverts to the TIME/WET screen.
• Operation reverts to the TIME/WET screen if neither button is pressed in 2 minutes.
SET DEPTH ALARM ON/OFF
Factory set ON, the DEPTH ALARM can also be set OFF. When set OFF, the Alarm will not sound
when Depth increases toward 330 FT (120 M).
To access SET DEPTH ALARM while viewing the SET 2 GO TO screen, press/release the A button
(3 times) until the Set screen appears (Fig. 40) -
• Alpha graphics DEEP and AL
• Set Point graphic ON (or OFF), flashing
> Pressing and releasing the S button toggles between ON and OFF.
Fig. 39 - Set Ascent
Alarm
Fig. 40 - Set Depth
Alarm