INSIGHT
A
S
A
S
LAST DIVE SCREENS
The LAST Main screen is accessible by pressing the A (Left) button 3 times while the TIME/WET
screen is being displayed (TIME/WET >> DATA >> PLAN >> LAST). It displays data for the most
recent dive conducted. Pressing the S (Right) button will access the ALT screen, if set for Nitrox,
which returns to the Main after 5 seconds or if S is pressed again.
LAST MAIN screen (Fig. 19A)
• Alpha graphic LAST
• Time of Day the dive Started with Down Arrow icon
• Time of Day the dive Ended with UP Arrow and TIME icons
• NITROX icon (blank if Air)
• Max Depth of the dive with FEET (or METERS) icon
• Elapsed Dive Time with MINUTES icon
• N2BG representing end of dive loading and max segment representing max during dive
LAST ALTERNATE screen (Nitrox only - Fig. 19B)
• Alpha graphic LAST
• Max PO2 during dive with MAXIMUM icon and graphic PO2
• NITROX icon
• Graphic ALt (indicating Alternate screen)
• FO2 Set Point with FO2% icon
• O2BG representing end of dive accumulation
Fig. 19A - Last Dive
Fig. 19B - Last Alternate