When the required number of modules are installed, the
assembly is tightened with a compression unit.
This system is available with a large number of various modules
and compression units, and it will also comply to screening and
EMC requirements.
Figure 12 Multi-diameter
system - The finishied
assembly
Standard type
1 Ensure that all the cables to be connected, are completely
isolated from any power sources.
- Switch off and remove the supply fuses from any units
or systems into which the cables are already connected.
2 Select the cable to be connected into the cabinet, and
select the cable gland through which the cable is to pass.
3 Slacken and remove the compression nut from the cable
gland, and extract the compression seal and the screen
collar from the body of the gland.
Note A minimum of 5 cm (recommended 5 - 10 cm) of slack cable
must be allowed, both inside and outside the cabinet, when
installing cables. This is to allow for vibration damping,
maintenance and measurement errors. Always double-check
your measurements before taking any irreversible actions.