11 Carefully thread the cable through the gland body till the
screen collar is tight into the gland body.
12 Slide the compression seal into the gland body till the
shoulder is hard up against the gland body.
13 Slide the compression nut over the compression seal and
engage the threads.
14 While holding the gland body to prevent it turning, and
pressing the cable into the gland, tighten the compression
nut onto the gland body.
15 Referring to the wiring diagram and ensuring that there is
5 to 10 cm. slack cable inside the cabinet, prepare and
connect the cable cores to the appropriate terminals within
the cabinet.
16 Secure the cable within the cabinet using cable clips.
17 Check the terminal connections against the wiring diagram
to ensure they are correct.
Follow the same procedure for all the cables and cable glands.
Once all the cables have been fitted:
18 Check the cabinet to ensure all tools and rubbish are
removed, then close the cabinet door.
Once all the system cables are connected and checked:
19 Take the appropriate safety measures, then replace the
fuses and apply power to the system.
20 Perform a system test to ensure the installation has been
conducted successfully.
Additional type 1 (842-093878)
1 Mount the cable gland body, and tighten it with the nuts
on each side of the cabinet wall.
2 Slide the metal washers, the rubber gasket and the
compression nut onto the cable in the order indicated in
the figure.
Refer to figure 14.
3 Bend the screen over the rubber gasket.
4 Push the rubber gasket and the two metal washers
carefully into the cable gland body.
5 While holding the gland body to prevent it turning, and
pressing the cable into the gland, tighten the compression
nut onto the gland body.