Simrad EQ60 SONAR User Manual


 
Operational procedures
43
857-164342 / Rev.C
Related topics
Header view, page 20
Bottom Detector, page 75
Enabling the depth alarms
You can set individual alarms for minimum and maximum
depth. You can also enable an alarm to sound off if the bottom
track is lost.
1 Position the cursor over the depth field in the Header
view, and click the right mouse button.
-TheBottom detector dialogue box opens.
2 Set the values for minimum and maximum depth alarm.
3 Enable the alarms by ticking the appropriate boxes.
4 Enable the BottomLostWarningif required.
5 Click Ok.
Related topics
Header view, page 20
Bottom Detector, page 75
Adding annotations
You can add several different annotations to the displayed and
printed information. All annotations are automatically
displayed, while you need to enable the annotations to be
printed.
Enable annotations to be printed
1 Select Print on the File menu.
-The
Printer and History dialogue box opens.
2 Under Text to printer, click Annotation.
3 Click OK to exit.
The annotations will be printed until this procedure is repeated.
Enter annotations
Three different annotations may be controlled from the
Annotations dialogue box.
1 Select Annotation on the
File menu.
-TheAnnotation dialogue box opens.
2 To enter a single text annotation to the display: