Simrad EQ60 SONAR User Manual


 
Instruction manual
73
857-164342 / Rev.C
BI 500
The BI 500 dialogue box is opened from the Install menu.
The EQ60 echo sounder may communicate on an ethernet line
with the BI 500 post-processing software. This dialogue box is
used to set up the parameters for this communication, and to
define which information the BI 500 shall receive.
Datagram
You can specify which datagrams to be transmitted to the BI
500 computer:
Parameter- Check this box if you want to transmit parameter
data. The parameters required by BI 500 are sound velocity,
frequency, pulse length and transducer type.
Echogram - Check this box if you want to transmit echogram
data (surface and/or bottom related). Note that this data is
required by the BI 500.
Echo Trace - Check this box if you want to transmit echo trace
data.
Navigation - Check this box if you want to transmit the
Navigation datagrams selected in the Navigation Interface
dialogue box. Navigational data is required if you intend to use
the map function in BI 500.