IBM SY33-0193-00 Marine RADAR User Manual


 
1. Find the SRN in the table.
If you cannot find the SRN
, refer to the
documentation for the subsystem or device. If you still cannot find the SRN, you
have a problem with the diagnostics, the microcode, or the documentation. Call
your support center for assistance.
2. Read carefully the “Action” you must do for the problem.
Do not exchange
adapters unless you are instructed to do so
.
3. Normally exchange only one adapter at a time. Always use instructions provided
with the system unit when exchanging adapters. After each adapter is exchanged,
go to “MAP 2410: SSA Repair Verification” on page 2410-1 to verify the repair.
SRN FRU List Problem
20PAA Device (45%)
(“Exchanging Disk Drives” on page 19).
SSA adapter card (45%)
External SSA cables (6%)
Internal SSA connections (4%)
(
Hardware Maintenance Manual
).
Description: An open SSA link has been detected.
Action: Run the Disk service aid to isolate the failure (see
“Service Aids and Other Utilities” on page 29).
If the SSA service aids are not available, go to the service
information for the unit in which the device is installed.
21PAA
to
29PAA
Device (45%)
(“Exchanging Disk Drives” on page 19).
SSA adapter card (45%)
External SSA cables (6%)
Internal SSA connections (4%)
(
Hardware Maintenance Manual
).
Description: An SSA ‘Threshold exceeded’ link error has been
detected.
Action: Go to “MAP 2010: START” on page 2010-1.
2A002 Device (50%)
(“Exchanging Disk Drives” on page 19).
SSA adapter card (50%)
Description: Async code 02 has been received. Probably, a
software error has occurred.
Action: Go to “Software and Microcode Errors” on page 12
before exchanging any FRUs.
2A003 Device (50%)
(“Exchanging Disk Drives” on page 19).
SSA adapter card (50%)
Description: Async code 03 has been received. Probably, a
software error has occurred.
Action: Go to “Software and Microcode Errors” on page 12
before exchanging any FRUs.
2A004 Device (50%)
(“Exchanging Disk Drives” on page 19).
SSA adapter card (50%)
Description: Async code 04 has been received. Probably, a
software error has occurred.
Action: Go to “Software and Microcode Errors” on page 12
before exchanging any FRUs.
2FFFF None Description: An async code that is not valid has been received.
Action: Go to “Software and Microcode Errors” on page 12.
303FF Device (100%)
(“Exchanging Disk Drives” on page 19).
Description: A SCSI status that is not valid has been received.
Action: Go to “Software and Microcode Errors” on page 12.
40000 SSA adapter card (100%) Description: The SSA adapter card has failed.
Action: Exchange the FRU for a new FRU.
40004 4 MB DRAM module 0 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 4 MB DRAM in adapter card module 0 has failed.
Action: Exchange the FRU for a new FRU.
40008 8 MB DRAM module 0 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: An 8 MB DRAM in adapter card module 0 has
failed.
Action: Exchange the FRU for a new FRU.
40016 16 MB DRAM module 0 (100%)
(“Exchanging DRAMs on the IBM
SerialRAID Adapter” on page 22).
Description: A 16 MB DRAM in adapter card module 0 has
failed.
Action: Exchange the FRU for a new FRU.
4 IBM SerialRAID Adapter Maintenance Information