MAP 2324 (continued)
051 (continued)
Start the DOS Configurator.
From the Main menu, select SSA Adapter List.
Select the required adapter from the SSA Adapter List.
Check whether a rebuild operation is running on any array.
IS A REBUILD OPERATION RUNNING ON ANY ARRAY?
Yes No
052
Go to Step 057.
053
Wait for the rebuild to complete.
Rerun concurrent diagnostics to the adapter.
Go to Step 054.
054
(From step 053)
IS THE PROBLEM SOLVED?
Yes No
055
Go to Step 057.
056
No further action is needed.
057
(From steps 052 and 055)
Start the DOS Configurator.
Open the adapter list and select the appropriate adapter.
Select System Resources from the adapter menu.
Select the arrays, one at a time, and check whether any array has one or more
unbuilt parity strides, or one or more unbuilt component strides.
(Step 057 continues)