IBM SY33-0193-00 Marine RADAR User Manual


 
RAID Checkout
You are now starting the RAID checkout procedure
069
(From MAP 2410 step 006 on page 2410-2)
(From steps 008, 026, 029, 064, and 067)
Using the DOS Configurator, open the adapter list and select the appropriate
adapter.
From the adapter menu select Rejected Disks.
Using the RSM configurator, go to the Logical View and select Rejected.
ARE ANY DISK DRIVES LISTED?
Yes No
070
Go to Step 075 on page 2324-16.
071
Run nonconcurrent diagnostics to all the disk drives that are listed as rejected.
Run the Certify service aid (see “Certify Disk” on page 35) to all the rejected disk
drives.
Go to Step 072.
072
(From steps 017 and 071)
IS ANY DISK DRIVE FAILING?
Yes No
073
Go to Step 075 on page 2324-16.
Note: A disk drive that is listed as rejected is not necessarily failing. For
example, the array might have rejected the disk drive because a power problem,
or an SSA link problem, caused that drive to become temporarily unavailable.
Under such conditions, the disk drive can be reused.
074
Exchange the failing disk drive for a new one (see “Exchanging Disk Drives” on
page 19).
(Step 074 continues)
MAPs 2324-15