MAP 2324 (continued)
022 (continued)
Using the DOS Configurator and Service Aids Utility, select the appropriate adapter,
then from the adapter menu select System Resources.
Select the failing array, then Select View Members.
Using the RSM configurator, go to the Logical View and select RAIDx, then select the
appropriate array to see the members.
Select the failing disk drive, and note the Resource Names of the disk drives that are
members of the array.
Ask the user create a backup of all the data from this array. Some data might not be
accessible.
When the backup has been created, ask the user to delete the array.
Run nonconcurrent diagnostics to each of the disk drives that you noted previously.
DO THE DIAGNOSTICS FAIL WHEN THEY ARE RUN TO A PARTICULAR DISK
DRIVE?
Yes No
023
Go to Step 025.
024
Exchange the failing disk drive for a new one (see “Exchanging Disk Drives” on
page 19).
Go to Step 090 on page 2324-18 to add the disk drive to the group of disk drives that
are available for use by the RAID manager.
025
(From step 023)
Run the Certify service aid (see “Certify Disk” on page 35) to each of the disk drives
that you noted previously.
DID THE CERTIFY SERVICE AID FAIL WHEN IT WAS RUN TO A PARTICULAR
DISK DRIVE?
Yes No
026
Ask the user to recreate the array.
Go to Step 069 on page 2324-15.
027
(Step 027 continues)
2324-6 IBM SerialRAID Adapter Maintenance Information