MAP 2324 (continued)
087 (continued)
WAS SRN 49100 LOGGED, BUT NO ERROR FOUND, WHEN CONCURRENT
DIAGNOSTICS WERE RUN?
Yes No
088
You have solved all the array problems.
089
An array was in the Exposed state, but is now in the Good state.
This problem might have occurred because a disk drive was temporarily removed from
the system.
Ensure that the power system turns on power to all the disk drives before, or when, it
turns on the power to the system unit.
090
(From steps 024, 030, 034, 040, 044, 062, 068, and 074)
HAS A FAILED DISK DRIVE BEEN EXCHANGED FOR A NEW DISK DRIVE?
Yes No
091
If you have repaired a power or cabling fault that caused the disk drive to be
missing from the system, the drive might now be in a rejected state. You must
change that disk drive into a usable disk drive:
Using the DOS Configurator, open the adapter list and select the appropriate
adapter.
from the adapter menu select Rejected Disks.
Using the RSM configurator, go to the Logical View and select Rejected.
Delete the disk drive that has been restored to the system. This action
changes the disk drive to a free resource.
Ask the customer to choose how the disk drive is to be configured:
Hot-spare
Attached resource
Remain as a free resource
092
If you exchanged the disk drive by using the procedure described in “Exchanging Disk
Drives” on page 19, the new disk drive is identified as a new resource.
(Step 092 continues)
2324-18 IBM SerialRAID Adapter Maintenance Information