IBM SY33-0193-00 Marine RADAR User Manual


 
SRN FRU List Problem
49700 None Description: The parity for the array is not complete.
Action: Go to “MAP 2010: START” on page 2010-1.
50000 SSA adapter card (100%) Description: The SSA adapter failed to respond to the device
driver.
Action: Exchange the FRU for a new FRU.
50001 SSA adapter card (100%) Description: A data parity error has occurred.
Action: Exchange the FRU for a new FRU.
50002 SSA adapter card (100%) Description: An SSA adapter DMA error has occurred.
Action: Exchange the FRU for a new FRU.
50004 SSA adapter card (100%) Description: Channel check.
Action: Exchange the FRU for a new FRU.
50005 SSA adapter card (100%) Description: A software error has occurred.
Action: Go to “Software and Microcode Errors” on page 12
before exchanging the FRU.
50006 SSA adapter card (100%) Description: A channel check has occurred.
Action: Exchange the FRU for a new FRU.
50008 SSA adapter card (100%) Description: Unable to read or write the PCI registers.
Action: Exchange the FRU for a new FRU.
50010 SSA adapter card (100%) Description: An SSA adapter or device drive protocol error has
occurred.
Action: Go to “Software and Microcode Errors” on page 12
before exchanging the FRU.
50012 SSA adapter card (100%) Description: The SSA adapter microcode has hung.
Action: Run nonconcurrent diagnostics to the SSA adapter.
If the diagnostics fail, exchange the FRU for a new FRU.
If the diagnostics do not fail, go to “Software and Microcode
Errors” on page 12 before exchanging the FRU.
D4000 SSA adapter card (100%) Description: The diagnostics cannot configure the SSA adapter.
Action: Exchange the FRU for a new FRU.
D4100 SSA adapter card (100%) Description: The diagnostics cannot open the SSA adapter.
Action: Exchange the FRU for a new FRU.
D4300 SSA adapter card (100%) Description: The diagnostics have detected an SSA adapter
POST failure.
Action: Exchange the FRU for a new FRU.
DFFFF SSA adapter card (100%) Note: The description and action for this SRN are valid only if
you have run diagnostics to the SSA attachment. If this SRN
has occurred because you have run diagnostics on some other
device, see the service information for that device. Description:
A command or parameter that has been sent or received is not
valid. This problem is caused either by the SSA adapter, or by
an error in the microcode.
Action: Go to “Software and Microcode Errors” on page 12
before exchanging the FRU.
Service Request Numbers (SRNs) 11