IBM SY33-0193-00 Marine RADAR User Manual


 
MAP 2324 (continued)
062 (continued)
Exchange the failing disk drive for a new one (see “Exchanging Disk Drives” on
page 19).
Go to Step 090 on page 2324-18 to add the disk drive to the group of disk drives that
are available for use by the RAID manager.
063
(From step 061)
Run the Certify service aid (see “Certify Disk” on page 35) to the disk drives that you
noted previously.
DID THE CERTIFY SERVICE AID FAIL WHEN RUN TO ANY PARTICULAR DISK
DRIVE?
Yes No
064
Ask the user to recreate the array.
Go to Step 069 on page 2324-15.
065
Run the Format service aid (see “Format Disk” on page 34) to the disk drive.
Run the Certify service aid to the disk drive again.
Go to Step 066.
066
(From step 065)
DID THE CERTIFY SERVICE AID FAIL AGAIN?
Yes No
067
Ask the user to recreate the array.
Go to Step 069 on page 2324-15.
068
Exchange the failing disk drive for a new one (see “Exchanging Disk Drives” on
page 19).
Go to Step 090 on page 2324-18 to add the disk drive to the group of disk drives that
are available for use by the RAID manager.
2324-14 IBM SerialRAID Adapter Maintenance Information