IBM SY33-0193-00 Marine RADAR User Manual


 
027 (continued)
Run the Format service aid (see “Format Disk” on page 34) to the disk drive.
Run the Certify service aid again to the disk drive.
Go to Step 028.
028
(From step 027)
DID THE CERTIFY SERVICE AID FAIL AGAIN?
Yes No
029
Ask the user to recreate the array.
Go to Step 069 on page 2324-15.
030
Exchange the failing disk drive for a new one (see “Exchanging Disk Drives” on
page 19).
Go to Step 090 on page 2324-18 to add the disk drive to the group of disk drives that
are available for use by the RAID manager.
031
(From step 010)
An array is in the Degraded state if one member disk drive of the array is missing, and
a write command has been sent to that array. When an array is in the Degraded state,
its data is not protected.
Using the SSA Configurator and Service Aids Utility, select the appropriate adapter,
then from the adapter menu select Rejected Disks.
Using the RSM configurator, go to the Logical View and select Rejected.
ARE ANY DISK DRIVES LISTED?
Yes No
032
A disk drive has not been detected by the adapter.
Go to Step 035 on page 2324-8.
033
(Step 033 continues)
MAPs 2324-7