IBM SY33-0193-00 Marine RADAR User Manual


 
MAP 2324 (continued)
013 (continued)
The status of the array changes to Good when the adapter can find all the member disk
drives of the array.
014
(From step 012)
Either more than one disk drive has failed, or an array that is not complete has been
connected to the IBM SerialRAID Adapter.
If no disk drives have been added to this system, go to Step 015.
If one or more disk drives have been added to this system, and those disk drives were
previously members of an array on this system or on another system, you must do the
following:
Do the actions that are described in “Deleting a Resource from the System Resource
List” on page 43.
Select the array that is in the Offline state, and delete it.
That array is now a free resource.
Do the actions that are described in “Removing a Disk Drive from an Array” on
page 43, and remove all the disk drives from the array.
You can now use those disk drives as free resources.
Locate and repair all failed disk drives, and make those disk drives available for the
creation of a new array.
Go to Step 015.
015
(From step 014)
Using the DOS Configurator select the appropriate adapter, then from the adapter
menu select Rejected Disks.
Using the RSM configurator, go to the Logical View and select Rejected.
ARE ANY DISK DRIVES LISTED?
Yes No
016
Ask the user to delete and recreate the array that is in the Offline state.
017
Run nonconcurrent diagnostics to all the disk drives that are listed as rejected.
(Step 017 continues)
2324-4 IBM SerialRAID Adapter Maintenance Information