IBM SY33-0193-00 Marine RADAR User Manual


 
009
Go to Step 010.
010
(From step 009)
Observe the Status column on the screen. If the status of any disk drive is ‘Power’,
that disk drive has detected a loss of redundant power or cooling. In the example
shown here, the fourth disk drive has detected such a loss.
On the RSM configurator this is shown as a red line in the Physical View, with the
added text Break.
┌───────────────────────────────────────────────────────────────────────┐
│ISSACFG SSA Configurator and Service Aids yymmdd DOS Version"
└───────────────────────────────────────────────────────────────────────┘
┌────────────────────────────┐
Main Menu
├────────────────────────────┤
┌─────────────────────────────────────┐
Disk Service Aids
├─────────────────────────────────────┤
│ Link SSA UID Status
│ Port A1
UIDxxxxx
UIDyxxxx
UID3xxxx
UID4xxxx Power
│ Port A2
│ Port B1
No disks
└──│ Port B2
└─────────────────────────────────────┘
┌────────────────────────────────────────────────────────────────┐
│<ESCAPE> Exit <ENTER> Select <F1> Help <F2> Format
│<F3> Certify <F4> ServiceMode <F5> Diagnostics <F9> FlashOn
│<F1> FlashOff
└────────────────────────────────────────────────────────────────┘
DO ONE OR MORE DISK DRIVES HAVE A ‘POWER’ STATUS?
Yes No
011
Go to Step 013 on page 2320-4.
012
Go to the START MAP for the unit in which the disk drive is installed.
MAPs 2320-3