MAP 2010: START
This MAP is the entry point to the MAPs for the IBM SerialRAID Adapter If you are not
familiar with these MAPs, read “Introduction to Using the MAPs” on page 49 first.
You might have been sent here because:
The system problem determination procedures sent you here.
Action from an SRN list sent you here.
A problem occurred during the installation of a disk subsystem or a disk drive.
Another MAP sent you here.
A customer observed a problem that was not detected by the system problem
determination procedures.
Attention: Unless the system unit needs to be turned off for some other reason,
do
not turn off the system when servicing the SSA loop
. Unit power cables and external
SSA cables that connect the devices to the system can be disconnected while that
system is running.
001
HAVE YOU BEEN SENT HERE FROM THE SRN LIST IN THIS BOOK?
Yes No
002
Go to Step 004.
003
Go to Step 007 on page 2010-2.
004
(From step 002)
DO YOU HAVE AN SRN?
Yes No
005
Using the DOS Configurator, select SSA Adapter List from the main menu.
Select the appropriate adapter from the list.
From the adapter menu, select Run Concurrent Diagnostics.
If an SRN is produced, go to “Service Request Numbers (SRNs)” on page 3.
(Step 005 continues)
MAPs 2010-1