8. Repeat the procedure given above for any other disk drive that you are changing.
9. If necessary, convert the newly-installed disk drive into a free resource (see the
configurator information in the
IBM SerialRAID Adapter: Installation and User's
Guide
).
Using the RSM Configurator
1. Start the RSM configurator and select the appropriate adapter from the Adapter
List.
2. On the Adapter View page, select the Physical View.
3. On the Physical View page, select the disk drive you want to change.
4. On the Disk View page, click on the Service Mode button at the bottom of the page
to put the disk into service mode.
If necessary use the Identify function to find the actual disk drive. Click FlashOn,
the Check light flashes on the selected disk drive; click FlashOff to remove the
function.
5. You can now remove the faulty disk drive and insert the replacement.
6. To reset Service Mode on the new disk, move back to the Physical View page and
click on the Reset Service Mode button at the base of the page.
If necessary, convert the newly-installed disk drive into a free resource (see the
configurator information in the
IBM SerialRAID Adapter: Installation and User's
Guide
).
Exchanging an Array Disk
This section describes how a disk is logically removed from an array and replaced by a
compatible Free Resource. Such action could be necessay, for example, to check a
disk drive that is giving a high level of read/write errors but has not been rejected from
the array.
This action is also necessary if an array disk develops a hard fault and there is no
hot-spare available. If this happens, at the next write operation the faulty disk is
automatically de-configured and moved to the Rejected list. In the array, the faulty disk
is replaced by a Blank Reserved. To restore the array to its full operational status you
need to replace the Blank Reserved in the array with a suitable Free Resource.
Note: If there was a Hot-Spare available when the array disk became faulty the
hot-spare is automatically integrated into the array and the faulty disk moved to the list
of Rejected disks. The procedure in this event is to convert the Rejected disk to a Free
resource, then change it as described in “Exchanging a Non-Array Disk Drive” on
page 19. The new disk can then be reassigned as a Hot-Spare to replace the one that
was used.