Icom FP-561 Marine Radio User Manual


 
| TEMP ADJ
64
5
INITIAL SETTING AFTER INSTALLATION
The following describes how to correct the water temperature detected by the
temperature sensor.
q Select SETTING on the Setting SET MODE using the [UP] or [DOWN] key and
press the [SET] key.
The SETTING screen will appear.
w Select TEMP ADJ using the [UP] or [DOWN] key and press the [SET] key.
The current water temperature is indicated in the temperature setting eld on the
SETTING screen.
e Enter the desired value into the temperature setting eld using the [UP] or
[DOWN] key and press the [SET] key.
The setting is saved.
* The permissible correction range is “–20 to +20.
r When you nish correcting the water temperature, press the [MENU] key.
You will return to the SET MODE screen.
The build-in GSP receiver of the system receives signals from the GPS, and the
GPS uses the WGS-84 geodetic reference system, a global geodetic reference
system.
The following describes how to select the geodetic reference system of nautical
charts you currently use, in order to avoid positioning errors due to differences
between the nautical charts and the WGS-84. (see pgs. 77, 78; DATUM TABLE)
q Select SETTING on the SET MODE screen using the [UP] or [DOWN] key and
press the [SET] key.
The SETTING screen will appear.
w Select DATUM using the [UP] or [DOWN] key and press the [SET] key.
e Move the geodetic system setting led using the [LEFT] or [RIGHT] key.
The selected digit in the eld is highlighted in yellow.
r Enter the value corresponding to the nautical charts you currently use using the
[UP] or [DOWN] key and press the [SET] key.
The setting is saved.
t When you nish setting geodetic data, press the [MENU] key.
You will return to the SET MODE screen.
The following describes how to correct the ship or destination bearing that
will be displayed on the coastline screen or other screens.
TRUE; True bearing, MAG; Magnetic bearing
q Select SETTING on the SET MODE screen using the [UP] or [DOWN] key and
press the [SET] key.
The SETTING screen will appear.
w Select BEARING using the [UP] or [DOWN] key and press the [SET] key.
e Select Tru e or Magnetic using the [LEFT] or [RIGHT] key and press [SET]
key.
The setting is saved.
r When you nish setting the azimuth, press the [MENU] key.
You will return to the SET MODE screen.
| DATUM
SETTING
AUTO GAIN
DRAFT ADJ
TEMP ADJ
DATUM
BEARING
COMPASS IND
TIME REF
OFFSET TIME
SPEED DATA
SPEED ADJ
NMEA OUT
BOD OUT
ON
7.5 FT
+ 2.4 °F
TEMP
000
TRUE
NOR
LOCAL
+ 9: 00
POS
24000 P/
SPEED
V1 . 5
WP
OFF
. °F
MAG
REVS
GMT
SENS
NM
0 . 0KT
V2 . 2
SHIP
CLR
CANC
ADJ
SET
SET
SETTING
AUTO GAIN
DRAFT ADJ
TEMP ADJ
DATUM
BEARING
COMPASS IND
TIME REF
OFFSET TIME
SPEED DATA
SPEED ADJ
NMEA OUT
BOD OUT
ON
7.5 FT
+ 2.4 °F
TEMP
123
TRUE
NOR
LOCAL
+ 9 : 00
POS
24000 P/
SPEED
V1 . 5
WP
OFF
. °F
MAG
REVS
GMT
SENS
NM
0 . 0KT
V2 . 2
SHIP
CLR
CANC
SEL
ADJ
SET
SET
| BEARING
SETTING
AUTO GAIN
DRAFT ADJ
TEMP ADJ
DATUM
BEARING
COMPASS IND
TIME REF
OFFSET TIME
SPEED DATA
SPEED ADJ
NMEA OUT
BOD OUT
ON
7.5 FT
+ 2.4 °F
TEMP
123
TRUE
NOR
LOCAL
8 : 30
POS
22000 P/
SPEED
V1 . 5
WP
OFF
. °F
MAG
REVS
GMT
SENS
NM
0 . 0KT
V2 . 2
SHIP
CLR
CANC
SEL
SET
SET