1. OPERATIONAL OVERVIEW
1-5
1.3 Turning the Unit On/Off
Press the [POWER/TX] key on the control unit to turn on the power. The
POWER lamp on the processor unit lights. A beep sounds and the equipment
proceeds in the sequence shown below, displaying product information, startup
test results and the chart usage disclaimer. The startup test checks the ROM,
RAM, internal battery and backup data for proper operation, displaying the
results for each as OK or NG (No Good). If NG appears try to press any key to
go to the chart disclaimer screen, then perform the diagnostic test as shown in
the paragraph “7.5 Diagnostics.”
RADAR PLOTTER
*
STATION NAME:
RADAR#
FURUNO ELECTRIC CO., LTD.
CHARTS AVAILABLE
LICENSE NO.
STARTUP TEST
ROM OK
RAM OK
BACKUP DATA OK
INTERNAL BATTERY OK
Î
Î
Product information Startup test Chart disclaimer
Host Name
Chart List
NONATIONALHYDROGRAPHIC
OFFICEHASVERIFIEDTHE
INFORMATIONINTHIS
COASTLINEDATACARDANDNONE
ACCEPTLIABILITYFORTHE
ACCURACYOFREPRODUCTIONOR
ANYMODIFICATIONSMADE
THEREAFTER.THISPRODUCTWITH
THISCOASTLINEDATACARD
DOESNOTREPLACETHE
REQUIREMENTTOUSETHE
APPROPRIATEPRODUCTSFOR
NAVIGATIONACCORDINGTO
NATIONALANDINTERNATIONAL
REGULATIONS.
PROGRAMNo.1950011XXX**
**=Programversionno.for
FURUNO/NAVIONICS
model.1950010XXXforC-MAPmodel.
XXX=programversionno.
* = "GD-1900C-BB Plotter" for GD-1900C-BB
#= Name determined at installation.
Startup sequence
For start up with the radar display, the magnetron takes from one minute to
two minutes and thirty seconds (depending or radar model) to warm up before
the radar can be operated. The time remaining for warming up the magnetron is
counted down at the center of the display.
You may press any key at the chart disclaimer screen to show the last-used
display, or wait several seconds to let the equipment do it for you.
To turn the unit off, press and hold down the [POWER/TX] key until the screen
goes dark (approx. 3 sec.). Note that if the network sounder is connected, it will
be turned off approx. three minutes after turning off the power.
Note: The first time you turn on the power (or any time the power is applied after
a memory reset), you are asked if you want to start the simulation mode,
which provides simulated operation of the equipment. Push the [ENTER]
knob to start the simulation mode, or press the [CLEAR] key to start
normal operation. For further details about the simulation mode, see the
paragraph “1.10 Simulation Display.”