Furuno 1823C-BB Marine RADAR User Manual


 
2. RADAR OPERATION
2-3
1. Press the [GAIN] key to show the “gain adjustment” soft keys, and the
last-used adjustment window appears. The example below shows the gain
sensitivity adjustment window. The gain soft keys shown depend on radar
source as shown below.
GAIN
ADJUST
319. 9
°
M
359.9 ˚R
11.70
nm
+
12/
H-UP
3nm
LP
GAIN SENSITIVITY
AUTO ROUGH
AUTO MODERATE
AUTO CALM
MAN
0
GAINA
A/C
SEA
B
A/C
RAIN
C
RETURNE
D
A/C AT
ON
/
OFF
When the radar source is the
M1700 series radar, this key's
label is changed to "FTC".
Gain adjustment soft key
2. Press the A:GAIN soft key to show the gain sensitivity setting window.
GAIN SENSITIVITY
AUTO ROUGH
AUTO MODERATE
AUTO CALM
MAN
0
Gain sensitivity window
3. Use the trackball to select AUTO ROUGH, AUTO MODERATE, AUTO CALM,
or MAN (manual) as appropriate. Select an AUTO option according to the
sea state.
4. For manual adjustment, rotate the [ENTER] knob to adjust, while observing
the radar echo. The range of adjustment is 0-100.
5. Press the [GAIN] key on the front panel or the E:RETURN soft key to finish.
offered by Busse-Yachtshop.de