Maretron DSM250-01 Marine Instruments User Manual


 
DSM250 User’s Manual
Page 90 Revision 1.4.16a
Figure 85 – Setting the Transducer Depth Offset in a DST110
With the offset value highlighted, you can change the offset by using the Increase and Decrease
keys ( or ). Once you have selected the desired offset, push the Enter key ( ) to complete
the transducer depth offset calibration. This procedure actually programs the offset value into the
DST110 such that all displays subsequently receive the offset information. This means you don’t have
to program multiple displays each with the corresponding offset information as the information is
stored at a single place (at the source).
6.10.7 Trip Log
The DSM250 is capable of clearing the trip log counter within a DST110 depth/speed/temperature
transducer. You zero the trip log by pressing the Enter key ( ) with the “Trip Log:” menu item
selected which results in the screen shown Figure 79. Pressing the Accept ( ) key while the
“Reset” menu item is selected will complete the operation. Resetting the trip log zeroes the DST110’s
trip log such that all displays receive a zeroed value (i.e., you don’t have to perform the operation
from other DSM200/DSM250 locations).
Figure 86 – Resetting the DST110 Trip Distance Log