Figure 60 – DCR100 Channel Configuration Screen (DCR Mode)
6.6.4.1.1 Label
This entry allows you to assign a text label to the device. This label is visible in Maretron analysis and
display products and allows you to easily identify the particular device.
6.6.4.1.2 Operating Mode
The operating mode of each channel may be set to either DCR (DC Relay), in which case the state of
the channel is controlled by “Circuit Breaker / Switch” controls in N2KView or “Switch/Breaker”
favorite screens in the DSM150/DSM250 displays. This section of the manual assumes the operating
mode has been set to “DCR”.
6.6.4.1.3 Switch Lock
The default state of a channel in DCR Switch Lock mode is “Unlocked”. In the Unlocked mode, the
channel may be turned on and off from network display devices. By setting the Switch Lock mode of
the channel to “Lock”, then channel will not change state until the Switch Lock mode has once again
been set to “Unlocked”.
6.6.4.1.4 Power Up State
This entry defines the state of the channel when the DCR100 is powered up.
You may set this entry
of “Off”, in which the channel powers up in the Off state (the solid-state relay is open). You may also
set this entry to “On”, in which the channel powers up in the On state (the solid-state relay is closed).
Finally, you may set this entry to “Previous”, in which the channel powers up to the state it was in
when power was previously removed.
6.6.4.1.5 Switch Control
This entry will show the current state of the relay channel, either “Off” (open) or “On” closed. You may
use this menu entry to turn the relay channel on or off.