Mitsubishi Electronics FR-D740-012 Marine Battery User Manual


 
Parameter listParameter list
62
4
PARAMETERS
Parameter List
Current detection
166
Output current detection signal
retention time
0 to 10s, 9999 0.1s 0.1s 124 166 06 86 2 
167
Output current detection operation
selection
0, 1 1 0 124 167 07 87 2
168
Parameter for manufacturer setting. Do not set.
168
Parameter for manufacturer setting. Do not set.
169 169
Cumulative
monitor clear
170 Watt-hour meter clear 0, 10, 9999 1 9999 128 170 0A 8A 2 ×
171 Operation hour meter clear 0, 9999 1 9999 128 171 0B 8B 2 × × ×
Input terminal function
assignment
178 STF terminal function selection
0 to 5, 7, 8, 10, 12,
14, 16, 18, 24, 25,
60, 62, 65 to 67, 9999
160113 178 12 92 2 ×
179 STR terminal function selection
0 to 5, 7, 8, 10, 12,
14, 16, 18, 24, 25,
61, 62, 65 to 67, 9999
1 61 113 179 13 93 2 ×
180 RL terminal function selection
0 to 5, 7, 8, 10, 12,
14, 16, 18, 24, 25,
62, 65 to 67, 9999
10113 180 14 94 2 ×
181 RM terminal function selection 1 1 113 181 15 95 2 ×
182 RH terminal function selection 1 2 113 182 16 96 2 ×
Output terminal function assignment
190 RUN terminal function selection
0, 1, 3, 4, 7, 8, 11 to 16,
25, 26, 46, 47, 64, 70,
80, 90, 91, 93, 95, 96,
98, 99, 100, 101, 103,
104, 107, 108,
111 to 116, 125, 126,
146, 147, 164, 170, 180,
190, 191, 193, 195,
196, 198, 199, 9999
1 0 119 190 1E 9E 2 ×
192 A,B,C terminal function selection
0, 1, 3, 4, 7, 8, 11 to 16,
25, 26, 46, 47, 64, 70,
80, 90, 91, 95, 96, 98,
99, 100, 101, 103, 104,
107, 108, 111 to 116,
125, 126, 146, 147, 164,
170, 180, 190, 191, 195,
196, 198, 199, 9999
199119 192 20 A0 2 ×
Multi-speed setting
232 Multi-speed setting (speed 8) 0 to 400Hz, 9999 0.01Hz 9999 89 232 28 A8 2
233 Multi-speed setting (speed 9) 0 to 400Hz, 9999 0.01Hz 9999 89 233 29 A9 2 
234 Multi-speed setting (speed 10) 0 to 400Hz, 9999 0.01Hz 9999 89 234 2A AA 2
235 Multi-speed setting (speed 11) 0 to 400Hz, 9999 0.01Hz 9999 89 235 2B AB 2 
236 Multi-speed setting (speed 12) 0 to 400Hz, 9999 0.01Hz 9999 89 236 2C AC 2
237 Multi-speed setting (speed 13) 0 to 400Hz, 9999 0.01Hz 9999 89 237 2D AD 2 
238 Multi-speed setting (speed 14) 0 to 400Hz, 9999 0.01Hz 9999 89 238 2E AE 2
239 Multi-speed setting (speed 15) 0 to 400Hz, 9999 0.01Hz 9999 89 239 2F AF 2 
240 Soft-PWM operation selection 0, 1 1 1 148 240 30 B0 2
241 Analog input display unit switchover 0, 1 1 0 153 241 31 B1 2 
244 Cooling fan operation selection 0, 1 1 1 228 244 34 B4 2
Slip
compensation
245 Rated slip 0 to 50%, 9999 0.01% 9999 78 245 35 B5 2 
246 Slip compensation time constant 0.01 to 10s 0.01s 0.5s 78 246 36 B6 2
247
Constant-power range slip
compensation selection
0, 9999 1 9999 78 247 37 B7 2 
249 Earth (ground) fault detection at start 0, 1 1 0 146 249 39 B9 2
250 Stop selection
0 to 100s,
1000 to 1100s,
8888, 9999
0.1s 9999
112,
117
250 3A BA 2 
251 Output phase loss protection selection 0, 1 1 1 146 251 3B BB 2
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read Write
Extended
Copy Clear
All clear
V/F
V/F
V/F
GP
MFVC
GP
MFVC
GP
MFVC