SRS-1050 Testing ( Appendix C
Page C-4
SELF TEST (MEMORY/LINE)
VOICE & DATA ALL GOOD
Program and Loop Switch
Test
If your SRS-1050 has the optional
data terminal adapter, pressing 5
displays the status of the Program
(PRG) and Loop switches that are
a part of the TA. The display
looks like this:
SELF TEST (PROGRAM SW/LOOP SW)
PROG RAM: OFF LOOP:NOR
Pressing the Program switch on
the back of the set changes
PROG RAM: OFF to PROG
RAM: ON. Pressing the Loop
switch changes LOOP: NOR to
LOOP: TEST. See your Data
User's Guide for the function of
these switches.
Exiting Test Mode
To exit test mode, remove power
and reapply it.
Table C-1 Self-Test Result Codes
Display Message Test Result
S/M ERROR CODE (01)...................SMCM, RAM, ROM test failed.
S/M ERROR CODE (02)...................Line SIU test failed.
S/M ERROR CODE (03)...................Line SIU test timed out.
S/M ERROR CODE (04)...................Line NT test failed; message received
............................................................does not match message sent.
S/M ERROR CODE (05)...................Line NT test timed out.
S/M ERROR CODE (06)...................Line NT test failed; no response
............................................................received.
S/M ERROR CODE (07)...................SMCM test timed out.
S/M ERROR CODE (07)...................SMCM, RCM test timed out.
RCM (02)
RCM ERROR CODE (01).................RCM RAM test failed.
RCM ERROR CODE (02).................RCM test timed out.
VOICE ALL GOOD...........................All tests passed.
VOICE & DATA ALL GOOD.........All tests passed (with data terminal