NEC HX4500 Life Jacket User Manual


 
Problem Solving 5-13
Alarm Indication during Operation
Table 5-2 lists the alarm indications displayed on LCD during server operation.
Table 5-2. Operational Error Codes and Messages
Error Indication Description
CPU Err #YZ
(Y:1-2)(Z:1-2)
0BYZ An error was detected on CPU #YZ.
CPU Error An error was detected on CPU.
CPU Thermal
(X:1-2)(Y:1-2)
0BXY CPU #XY overheated.
CPU Thermal CPU overheated.
ISA Error
(X: 1-2)
050X An error was detected on ISA board slot #X.
ISA Error An error was detected on ISA boards.
HDD Thermal 1060 The internal hard disks overheated.
Memory Err
(X:1-8) (Y:1-2)
22XY A DIMM error was detected. X = bank. Y = 1 (lower) or 2 (upper)
PCI PERR# A parity error was detected on PCI boards.
PCI PERR# 0901 A parity error was detected on PCI boards slot #11 or #12.
PCI PERR# 0902 A parity error was detected on PCI boards slot #21, #22 or #23.
PCI PERR# 0903 A parity error was detected on PCI boards slot #31, #32, #33 or
#34.
PCI SERR# An error was detected on PCI boards or system I/O board.
PCI SERR# 0A01 An error was detected on PCI boards slot #11 or #12.
PCI SERR# 0A02 An error was detected on PCI boards slot #21, #22 or #23.
PCI SERR# 0A03 An error was detected on PCI boards slot #31, #32, #33 or #34.
POW Major B 10F0 An error was detected on the system power supply.
POW Major E 10F1 An error was detected on the disk expansion cabinet power
supply.
Power +3.3V 1012 An abnormal +3.3V was detected.
Power +5V 1013 An abnormal +5V was detected.
Power +12V 1014 An abnormal +12V was detected.
Power –12V 1015 An abnormal –12V was detected.
Power –5V 1016 An abnormal –5V was detected.