NEC HX4500 Life Jacket User Manual


 
5-14 Problem Solving
Table 5-2. Operational Error Codes and Messages (cont’d)
Error Indication Description
Power CPU#11 1010 An abnormal voltage was detected for CPU #11.
Power CPU#12 1011 An abnormal voltage was detected for CPU #12.
Power CPU#21 1020 An abnormal voltage was detected for CPU #21.
Power CPU#22 1021 An abnormal voltage was detected for CPU #22.
Thermal Hi 10X7
(X:1-2)
A cabinet overheated error was detected.
WDT-Timeout 0C00 The watchdog timer timed out.
Unknown SMI An illegal interrupt occurred.
CPU Error Messages
The system can have up to four processors. If an error occurs in a processor (or
VRM), the processor (or VRM) location is displayed on the LCD as follows:
CPU #11 1st primary CPU board processor
CPU #12 2nd primary CPU board processor
CPU #21 1st secondary CPU board processor
CPU #22 2nd secondary CPU board processor
In addition, it is also possible to know the CPU location in the BIOS Setup
utility (by CPU Configuration in the Advanced menu).
Memory Error Messages
The system can have up to sixteen DIMMs. If an error occurs in memory, the
DIMM location is displayed on the LCD as a combination of two numerals
specifying the bank and socket. The numerals in the error message correspond
to the lower two digits of the number of the relevant DIMM memory socket on
the CPU base board.
In addition, it is also possible to know the DIMM location in the BIOS Setup
utility (by Memory Configuration in the Advanced menu).