Standard Horizon CPV550 Marine GPS System User Manual


 
Page 90 CPV550
28, 84, 85, 86, and 87. Call the marine operator and identify yourself by your vessel’s name,
The marine operator will then ask you how you will pay for the call (telephone credit card,
collect, etc.) and then link your radio transmission to the telephone lines.
The marine telephone company managing the VHF channel you are using may charge a
link-up fee in addition to the cost of the call.
18.9 OPERATING ON CHANNELS 13 AND 67
Channel 13 is used at docks and bridges and by vessels maneuvering in port. Messages
on this channel must concern navigation only, such as meeting and passing in restricted
waters.
Channel 67 is used for navigational traffic between vessels.
By regulation, power is normally limited to 1 Watt on these channels. Your radio is
programmed to automatically reduce power to this limit on these channels. However, in
certain situations it may be necessary to temporarily use a higher power. See page 89
([H/L] key) for means to temporarily override the low-power limit on these two channels.
18.10 DUAL WATCH (TO PRIORITY CHANNEL)
Dual watch allows the radio to monitor one channel and the assigned Priority channel. By
default the priority channel is set to 16, however the priority channel may be changed by
referring to section “18.11.3 Priority Channel Set.”
1. Adjust [SQL] until the background noise disappears.
2. Select the channel you wish to dual watch to “Priority channel” by
rotating the channel knob.
3. Press [DW].
4. The CPV550 will scan between Priority channel and the channel that
was selected in step 2.
5. If a transmission is received on the channel selected in step 2, the CPV550 will dual
watch between the working channel and the Priority channel.
6. To stop Dual Watch, press [DW] again.
18.11 SCANNING
Allows the user to select the scan type from Memory scan or Priority scan. “Memory scan”
scans the channels that were programmed into memory. “Priority scan” scans the channels
programmed in memory with the priority channel.
18.11.0 Selecting the Scan Type
1. Select the chart page and press the [MENU] key two times. Move the ShuttlePoint knob
to highlight
RADIO SETUP and press [ENT] or move the ShuttlePoint knob to the right.
2. Move the ShuttlePoint knob to highlight
VHF SETTINGS and press [ENT] or move the
ShuttlePoint knob to the right.
3. Move the ShuttlePoint knob to highlight
SCAN and press [ENT] or move the ShuttlePoint
knob to the right.
4. Another popup window will be shown with
Priority and Memory, move the ShuttlePoint