Emerson Process Management 1153 SERIES D Marine Radio User Manual


 
Reference Manual
00809-0100-4388, Rev BA
January 2008
6-3
Rosemount 1153 Series D
Figure 6-1. Qualified Life vs.
Ambient Temperature.
PERFORMANCE
SPECIFICATIONS
Based on zero-based ranges under reference conditions.
Accuracy
±0.25% of calibrated span; includes combined effects of linearity, hysteresis,
and repeatability
Dead Band
None
Drift
±0.2% of upper range limit for 30 months (±0.3% of upper range limit for
Range Code 0)
Temperature Effect
Per 100 °F (55.6 °C) ambient temperature change:
Overpressure Effect
Rosemount 1153DD:
Maximum zero shift after 2,000 psi (13.8 MPa) overpressure:
Electronics
Qualified Life
Temperature (°F)
Time (Years)
Module
Qualified Life
Range Code Temperature Effect
3 ±(1.5% of upper range limit + 1.0% span)
4–9 ±(0.75% of upper range limit + 0.5% span)
0 ±(1.13% of upper range limit + 0.5% span)
Range Code Overpressure Effect
3, 4 ±0.25% of upper range limit
5 ±1.0% of upper range limit
6, 7 ±3.0% of upper range limit